QUICKFIT® Stirrer Gland, ground cone NS 29/32
- Manufactured from 3.3 expansion borosilicate glass complying with ISO 3585 (ASTM E-438 Type 1 Class A)
- Comprises parallel ground glass sleeve with cup to accept a suitable lubricant
- Designed to facilitate the use of stirrer shafts with jointed glass flasks and vessels
- Holds a vacuum down to 0.1 torr (13.3Pa)
- Supplied complete with screwcaps, rubber rings and PTFE washers
- Provides a vapour-tight seal between paddle and flask
View Product Specifications
Catalog Number:
Product Overview
Instructions for Use: Lubricant: The lubricant may be any relatively non-volatile compound suitable for use with the reaction in hand, provided its viscosity does not exceed that of glycerol. Typical lubricants are spindle oil and liquid paraffin. Speed: The stirrer should not be run at speeds in excess of 700rpm. When lubricants of high viscosity are used, rotation should commence at approximately 100rpm and should be gradually increased to maximum speed over 10 minutes. Assembly: Attach the stirrer to the sleeve of the gland by tightening the plastic screwcap. The gland will be damaged if rotated when dry and the ground surfaces must be smeared with lubricant before assembly. Care must be taken to ensure that the ground surfaces are clean and free from dust or grit before use.
Specifications
| Anchor stirrer d (mm) | 11 |
| Remarks | To fit stirrer shaft diameter 11mm |
| Thread | 24mm |
| Cone (NS) | 29/32 |
| Quantity | 5 |
Learn about the physical and chemical properties of our glass, plastic and rubber materials.
View Technical Information
Product Overview
Product Overview
Instructions for Use: Lubricant: The lubricant may be any relatively non-volatile compound suitable for use with the reaction in hand, provided its viscosity does not exceed that of glycerol. Typical lubricants are spindle oil and liquid paraffin. Speed: The stirrer should not be run at speeds in excess of 700rpm. When lubricants of high viscosity are used, rotation should commence at approximately 100rpm and should be gradually increased to maximum speed over 10 minutes. Assembly: Attach the stirrer to the sleeve of the gland by tightening the plastic screwcap. The gland will be damaged if rotated when dry and the ground surfaces must be smeared with lubricant before assembly. Care must be taken to ensure that the ground surfaces are clean and free from dust or grit before use.
Specifications
Specifications
| Anchor stirrer d (mm) | 11 |
| Remarks | To fit stirrer shaft diameter 11mm |
| Thread | 24mm |
| Cone (NS) | 29/32 |
| Quantity | 5 |
Learn about the physical and chemical properties of our glass, plastic and rubber materials.
View Technical Information