KIMBLE® KONTES® Micro DUALL® Tissue Grinder, all-glass, with threaded tube and screw cap
- Manufactured from borosilicate glass 3.3
- Can serve as a storage vessel following homogenization. Centrifugation, concentrations and lyophillization can be accomplished without a transfer.
- Flat base allows tube to stand upright without support
- Heavy wall construction of tube minimizes breakage
- Capacities shown are without the pestle inserted
- Supplied complete with pestle, tube, phenolic cap and PTFE liner
- Replacement components are available and completely interchangeable
- Clearance between pestles and tubes is 0.004 " to 0.006 "
Products
Pestle and Tube

| Catalog No | Main Article Description | Size | Nominal Capacity (mL) | Thread | Pestle Length (mm) | Quantity | |
|---|---|---|---|---|---|---|---|
| 885490-0017 | Pestle and Tube | 17 | 0.3 | 13-425 | 148 | 1 Kit | Find a distributor |
| 885490-0019 | Pestle and Tube | 19 | 1 | 13-425 | 148 | 1 Kit | Find a distributor |
| 885490-0020 | Pestle and Tube | 20 | 3 | 20-400 | 165 | 1 Kit | Find a distributor |
| 885490-0021 | Pestle and Tube | 21 | 5 | 20-400 | 165 | 1 Kit | Find a distributor |
Pestle only

| Catalog No | Size | Pestle Length (mm) | Pestle Shaft OD (mm) | Quantity | |
|---|---|---|---|---|---|
| 885491-0017 | 17 & 19 | 148 | 6 | 1 | Find a distributor |
| 885491-0020 | 20 & 21 | 165 | 9 | 1 | Find a distributor |
Tube only

| Catalog No | Main Article Description | Size | Nominal Capacity (mL) | Thread | Pestle Length (mm) | Quantity | |
|---|---|---|---|---|---|---|---|
| 885492-0017 | Tube only | 17 | 0.3 | 13-425 | - | 1 | Find a distributor |
| 885492-0019 | Tube only | 19 | 1 | 13-425 | - | 1 | Find a distributor |
| 885492-0020 | Tube only | 20 | 3 | 20-400 | - | 1 | Find a distributor |
| 885492-0021 | Tube only | 21 | 5 | 20-400 | - | 1 | Find a distributor |
Specifications
Product specifications are found on the product detail pages. Click on the product catalog number in the table above to view the individual product specifications.
Product Overview
Tissue grinders produce homogenates by a combination of shearing and compression actions. The tissue sample is progressively ground (sheared) into smaller pieces at the rounded end of the pestle as the spinning pestle is lowered into the tube. As the pestle is forced lower into the tube, the sample is displaced and forced between the straight outside wall of the pestle and the inside wall of the tube, compressing the tissue cells until they rupture. When the tube is pulled away from the pestle, a slight vacuum is created that pulls the sample back past the compression area, resulting in an additional homogenization stroke. The degree of homogenization is controlled by the clearance between the pestle’s and tube’s cylindrical section (radial distance usually 0.002 - 0.003 inches), the rotational speed of the pestle, and the number of compression strokes made.
Products
Products
Pestle and Tube

| Catalog No | Main Article Description | Size | Nominal Capacity (mL) | Thread | Pestle Length (mm) | Quantity | |
|---|---|---|---|---|---|---|---|
| 885490-0017 | Pestle and Tube | 17 | 0.3 | 13-425 | 148 | 1 Kit | Find a distributor |
| 885490-0019 | Pestle and Tube | 19 | 1 | 13-425 | 148 | 1 Kit | Find a distributor |
| 885490-0020 | Pestle and Tube | 20 | 3 | 20-400 | 165 | 1 Kit | Find a distributor |
| 885490-0021 | Pestle and Tube | 21 | 5 | 20-400 | 165 | 1 Kit | Find a distributor |
Pestle only

| Catalog No | Size | Pestle Length (mm) | Pestle Shaft OD (mm) | Quantity | |
|---|---|---|---|---|---|
| 885491-0017 | 17 & 19 | 148 | 6 | 1 | Find a distributor |
| 885491-0020 | 20 & 21 | 165 | 9 | 1 | Find a distributor |
Tube only

| Catalog No | Main Article Description | Size | Nominal Capacity (mL) | Thread | Pestle Length (mm) | Quantity | |
|---|---|---|---|---|---|---|---|
| 885492-0017 | Tube only | 17 | 0.3 | 13-425 | - | 1 | Find a distributor |
| 885492-0019 | Tube only | 19 | 1 | 13-425 | - | 1 | Find a distributor |
| 885492-0020 | Tube only | 20 | 3 | 20-400 | - | 1 | Find a distributor |
| 885492-0021 | Tube only | 21 | 5 | 20-400 | - | 1 | Find a distributor |
Specification
Specifications
Product specifications are found on the product detail pages. Click on the product catalog number in the table above to view the individual product specifications.
Product Overview
Product Overview
Tissue grinders produce homogenates by a combination of shearing and compression actions. The tissue sample is progressively ground (sheared) into smaller pieces at the rounded end of the pestle as the spinning pestle is lowered into the tube. As the pestle is forced lower into the tube, the sample is displaced and forced between the straight outside wall of the pestle and the inside wall of the tube, compressing the tissue cells until they rupture. When the tube is pulled away from the pestle, a slight vacuum is created that pulls the sample back past the compression area, resulting in an additional homogenization stroke. The degree of homogenization is controlled by the clearance between the pestle’s and tube’s cylindrical section (radial distance usually 0.002 - 0.003 inches), the rotational speed of the pestle, and the number of compression strokes made.