Pyrex® Automatic Burette, Class AS, Schellbach stripe, with PTFE key and intermediate stopcock, 25 mL

  • Complies with ISO 385 and DIN 12700
  • Manufactured from borosilicate glass 3.3.
  • With automatic zero facility
  • Intermediate stopcock facilitates easy drainage of liquid back into reservoir
  • Blue enamel graduations with Schellbach stripe
  • Schellbach burette tube with vertical white stripe and central blue ribbon - facilitates accurate reading of the meniscus - exact position of the meniscus is clearly defined where the blue ribbon splits into a wide and narrow band
  • 1.5mm bore PTFE key stopcock
  • All automatic burettes feature a Quickfit® cone NS 29/32.
Find a distributor
Catalog Number:
Product Overview
These automatic burettes feature the Schellbach vertical white stripe with a central blue ribbon to make the accurate reading of the meniscus much easier than a conventional burette. Their precise scaling makes them particularly suitable for titrimetric purposes. The amount of liquid required for titration, but previously unknown, can be read off very accurately after the reaction has been completed. Adjustment is made to drain ("Ex") for + 20 °C reference temperature. This means that the quantities can be taken exactly according to the scale, since the adhesion of the liquid to the glass was taken into account during calibration. The tolerances for the volume correspond to the error limits of ISO and DIN.

Specifications

Specifications
Remarks Burette only
Tolerance (mL) ± 0.03
Capacity (mL) 25
Cone (NS) 29/32
Graduation Intervals (mL) 0.05
Quantity 1
Product Overview
Product Overview
These automatic burettes feature the Schellbach vertical white stripe with a central blue ribbon to make the accurate reading of the meniscus much easier than a conventional burette. Their precise scaling makes them particularly suitable for titrimetric purposes. The amount of liquid required for titration, but previously unknown, can be read off very accurately after the reaction has been completed. Adjustment is made to drain ("Ex") for + 20 °C reference temperature. This means that the quantities can be taken exactly according to the scale, since the adhesion of the liquid to the glass was taken into account during calibration. The tolerances for the volume correspond to the error limits of ISO and DIN.
Specifications

Specifications

Specifications
Remarks Burette only
Tolerance (mL) ± 0.03
Capacity (mL) 25
Cone (NS) 29/32
Graduation Intervals (mL) 0.05
Quantity 1
Related Products