KIMBLE® KONTES® Improved, Arsine, Generator

  • Compact design requires less set-up time and is easier to clean due to the elimination of the ball and socket joint found in item 241100
  • Glass beads may be added to the absorber tube to enhance the mixing of the generated gas through the silver diethyldithiocarbamate
  • Supplied with one polyacetal clamp
  • Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type 1 and ASTM E438, Type 1, Class A requirements
Products
Catalog No Capacity (mL) Joint Size (mm) Width (mm) Overall Height (mm) Price Quantity

Specifications

Product specifications are found on the product detail pages. Click on the product catalog number in the table above to view the individual product specifications.

Product Overview
Designed for multiple arsenic determinations using a colorimetric assay as described in the 22nd Edition of Standard Methods for the Examination of Water and Wastewater, Method 3500-As B. KIMBLE® Chase arsine generators conform to ASTM, USP, and EPA specifications. The lead acetate-impregnated glass wool is inserted above the Standard Taper 24/40 joint. A sample containing arsenic is placed within the flask and converted to arsine gas. Hydrogen sulfide is removed from the sample as the gas is generated by lead acetate-impregnated glass wool packed within the scrubber cavity. The absorber tube, containing the reagent silver diethyldithiocarbamate, absorbs the arsine gas and forms a red complex. This product is transferred to a cuvette, and its visible spectrum is then recorded on a colorimeter or spectrometer.
Products
Products
Catalog No Capacity (mL) Joint Size (mm) Width (mm) Overall Height (mm) Price Quantity
Specification

Specifications

Product specifications are found on the product detail pages. Click on the product catalog number in the table above to view the individual product specifications.

Product Overview
Product Overview
Designed for multiple arsenic determinations using a colorimetric assay as described in the 22nd Edition of Standard Methods for the Examination of Water and Wastewater, Method 3500-As B. KIMBLE® Chase arsine generators conform to ASTM, USP, and EPA specifications. The lead acetate-impregnated glass wool is inserted above the Standard Taper 24/40 joint. A sample containing arsenic is placed within the flask and converted to arsine gas. Hydrogen sulfide is removed from the sample as the gas is generated by lead acetate-impregnated glass wool packed within the scrubber cavity. The absorber tube, containing the reagent silver diethyldithiocarbamate, absorbs the arsine gas and forms a red complex. This product is transferred to a cuvette, and its visible spectrum is then recorded on a colorimeter or spectrometer.