KIMBLE® KONTES® Potter-Elvehjem Tissue Grinder, with PTFE Pestle and Graduated Glass Tube

  • Manufactured from borosilicate glass 3.3
  • Radial serrations on the lower portion of the pestle deliver the homogenate into the cylindrical portion of the tube
  • Graduated tube; graduations are fused into the glass
  • Replacement components are available and completely interchangeable
  • 4 mL tubes have a clearance of 0.003-0.005 " between pestles and tubes
  • 10 mL tubes have a clearance of 0.004-0.006 " between pestles and tubes
  • 30 mL tubes have a clearance of 0.005-0.007 " between pestles and tubes
  • 55 mL tubes have a clearance of 0.006-0.009 " between pestles and tubes
Product Overview
Tissue grinders produce homogenates by a combination of shearing and compression actions. The tissue sample is progressively ground (sheared) into smaller pieces at the rounded end of the pestle as the spinning pestle is lowered into the tube. As the pestle is forced lower into the tube, the sample is displaced and forced between the straight outside wall of the pestle and the inside wall of the tube, compressing the tissue cells until they rupture. When the tube is pulled away from the pestle, a slight vacuum is created that pulls the sample back past the compression area, resulting in an additional homogenization stroke. The degree of homogenization is controlled by the clearance between the pestle’s and tube’s cylindrical section (radial distance usually 0.002 - 0.003 inches), the rotational speed of the pestle, and the number of compression strokes made. We offer three basic types of tissue grinders: Dounce, DUALL and Potter-Elvehjem. The Potter-Elvehjem tissue grinder has rounded shape on the lower portion of the pestle where th sample is progressively ground smaller. Ground glass pestle versions are suited for connective tissues whereas PTFE pestle versions are used with softer tissues.
Products
Pestle and Tube
Catalog No Main Article Description Size Nominal Capacity (mL) Graduation Range (mL) Tube Length (mm) Price Quantity
Pestle only
Catalog No Size Pestle B Small Clearance (in) Price Quantity
Tube only
Catalog No Size Graduation Range (mL) Tube Length (mm) Tube Reservoir OD (mm) Price Quantity
Product Overview
Product Overview
Tissue grinders produce homogenates by a combination of shearing and compression actions. The tissue sample is progressively ground (sheared) into smaller pieces at the rounded end of the pestle as the spinning pestle is lowered into the tube. As the pestle is forced lower into the tube, the sample is displaced and forced between the straight outside wall of the pestle and the inside wall of the tube, compressing the tissue cells until they rupture. When the tube is pulled away from the pestle, a slight vacuum is created that pulls the sample back past the compression area, resulting in an additional homogenization stroke. The degree of homogenization is controlled by the clearance between the pestle’s and tube’s cylindrical section (radial distance usually 0.002 - 0.003 inches), the rotational speed of the pestle, and the number of compression strokes made. We offer three basic types of tissue grinders: Dounce, DUALL and Potter-Elvehjem. The Potter-Elvehjem tissue grinder has rounded shape on the lower portion of the pestle where th sample is progressively ground smaller. Ground glass pestle versions are suited for connective tissues whereas PTFE pestle versions are used with softer tissues.
Products
Products
Pestle and Tube
Catalog No Main Article Description Size Nominal Capacity (mL) Graduation Range (mL) Tube Length (mm) Price Quantity
Pestle only
Catalog No Size Pestle B Small Clearance (in) Price Quantity
Tube only
Catalog No Size Graduation Range (mL) Tube Length (mm) Tube Reservoir OD (mm) Price Quantity
Related Products