KIMBLE® KONTES® Improved, Arsine, Generator
- Compact design requires less set-up time and is easier to clean due to the elimination of the ball and socket joint found in item 241100
- Glass beads may be added to the absorber tube to enhance the mixing of the generated gas through the silver diethyldithiocarbamate
- Supplied with one polyacetal clamp
- Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type 1 and ASTM E438, Type 1, Class A requirements
Product Overview
Designed for multiple arsenic determinations using a colorimetric assay as described in the 22nd Edition of Standard Methods for the Examination of Water and Wastewater, Method 3500-As B. KIMBLE® Chase arsine generators conform to ASTM, USP, and EPA specifications. The lead acetate-impregnated glass wool is inserted above the Standard Taper 24/40 joint. A sample containing arsenic is placed within the flask and converted to arsine gas. Hydrogen sulfide is removed from the sample as the gas is generated by lead acetate-impregnated glass wool packed within the scrubber cavity. The absorber tube, containing the reagent silver diethyldithiocarbamate, absorbs the arsine gas and forms a red complex. This product is transferred to a cuvette, and its visible spectrum is then recorded on a colorimeter or spectrometer.
Products
Catalog No | Capacity (mL) | Joint Size (mm) | Width (mm) | Overall Height (mm) | Price | Quantity |
---|---|---|---|---|---|---|
241160-0000 | 125 | 24/40 | 65 | 285 | $199.84 /Case of 1 |
Product Overview
Product Overview
Designed for multiple arsenic determinations using a colorimetric assay as described in the 22nd Edition of Standard Methods for the Examination of Water and Wastewater, Method 3500-As B. KIMBLE® Chase arsine generators conform to ASTM, USP, and EPA specifications. The lead acetate-impregnated glass wool is inserted above the Standard Taper 24/40 joint. A sample containing arsenic is placed within the flask and converted to arsine gas. Hydrogen sulfide is removed from the sample as the gas is generated by lead acetate-impregnated glass wool packed within the scrubber cavity. The absorber tube, containing the reagent silver diethyldithiocarbamate, absorbs the arsine gas and forms a red complex. This product is transferred to a cuvette, and its visible spectrum is then recorded on a colorimeter or spectrometer.
Products
Products
Catalog No | Capacity (mL) | Joint Size (mm) | Width (mm) | Overall Height (mm) | Price | Quantity |
---|---|---|---|---|---|---|
241160-0000 | 125 | 24/40 | 65 | 285 | $199.84 /Case of 1 |
Related Products