KIMBLE® KONTES® Dounce Tissue Grinder, with two glass pestles and tube, 100 mL

  • Manufactured from borosilicate glass 3.3
  • Designed primarily for cellular work where the nucleus remains intact after homogenization.
  • All-glass construction
  • Two pestles are supplied with each complete unit
  • Large clearance pestle is used for the initial sample reduction
  • Small clearance pestle is used to form the final homogenate
  • Replacement components are available and completely interchangeable
$533.01 USD/Case of 1
Currently Out of Stock
Catalog Number:
Product Overview
Tissue grinders produce homogenates by a combination of shearing and compression actions. The tissue sample is progressively ground (sheared) into smaller pieces at the rounded end of the pestle as the spinning pestle is lowered into the tube. As the pestle is forced lower into the tube, the sample is displaced and forced between the straight outside wall of the pestle and the inside wall of the tube, compressing the tissue cells until they rupture. When the tube is pulled away from the pestle, a slight vacuum is created that pulls the sample back past the compression area, resulting in an additional homogenization stroke. The degree of homogenization is controlled by the clearance between the pestle’s and tube’s cylindrical section (radial distance usually 0.002 - 0.003 inches), the rotational speed of the pestle, and the number of compression strokes made.

Specifications

Specifications
Tube Length (mm) 232
Nominal Capacity (mL) 100
Pestle B Small Clearance (in) 0.0005-0.0055
Pestle A Large Clearance (in) 0.0020-0.0100
Quantity 1 Kit
Product Overview
Product Overview
Tissue grinders produce homogenates by a combination of shearing and compression actions. The tissue sample is progressively ground (sheared) into smaller pieces at the rounded end of the pestle as the spinning pestle is lowered into the tube. As the pestle is forced lower into the tube, the sample is displaced and forced between the straight outside wall of the pestle and the inside wall of the tube, compressing the tissue cells until they rupture. When the tube is pulled away from the pestle, a slight vacuum is created that pulls the sample back past the compression area, resulting in an additional homogenization stroke. The degree of homogenization is controlled by the clearance between the pestle’s and tube’s cylindrical section (radial distance usually 0.002 - 0.003 inches), the rotational speed of the pestle, and the number of compression strokes made.
Specifications

Specifications

Specifications
Tube Length (mm) 232
Nominal Capacity (mL) 100
Pestle B Small Clearance (in) 0.0005-0.0055
Pestle A Large Clearance (in) 0.0020-0.0100
Quantity 1 Kit